Keywords

Lighting, Post-Occupational Evaluation (POE), technical, ventilation

Document Type

Article

Abstract

This study Post-Occupational Evaluation (POE), aims to determine whether the natural lighting and ventilation openings in theoretical rooms at SMK XYZ have met the standards or not. The review of technical aspects focused on lighting and ventilation issues. This research is descriptive, evaluative, with the POE method at the investigative level, making 13 theoretical rooms as research objects and 156 students or 12 students per class as research subjects. The research instrument is a measuring instrument plus a questionnaire as data to strengthen the study results. Data collection techniques with observation and recording of primary data and secondary studies. The data analysis technique used descriptive quantitative. The condition of the theoretical space at SMK XYZ for the KBM process does not meet standards, such as natural lighting of the theoretical room in 11 of the 12 existing rooms; inlet and outlet area, the elevation of ventilation holes at the inlet throughout the theory room.

Page Range

133-145

Issue

2

Volume

11

Digital Object Identifier (DOI)

10.21831/jpv.v11i2.41169

Source

https://journal.uny.ac.id/index.php/jpv/article/view/41169

References

Cannon, M. D., & Edmondson, A. C. (2005). Failing to learn and learning to fail (intelligently): How great organizations put failure to work to innovate and improve. Long Range Planning, 38(3), 299-319. https://doi.org/10.1016/j.lrp.2005.04.005

Doelle, L. L. (1993). Akustik lingkungan (L. Prasetio (trans.)). Erlangga.

Elfajri, I. (2016). Evaluasi pasca huni ruang perawatan intensif RS PKU Muhammadiyah Yogyakarta Unit II [Universitas Muhammadiyah Yogyakarta]. http://repository.umy.ac.id/handle/123456789/9093

Gonzalez-Caceres, A., Bobadilla, A., & Karlshøj, J. (2019). Implementing post-occupancy evaluation in social housing complemented with BIM: A case study in Chile. Building and Environment, 158, 260-280. https://doi.org/10.1016/j.buildenv.2019.05.019

Hauge, Ã…. L., Thomsen, J., & Berker, T. (2011). User evaluations of energy efficient buildings: Literature review and further research. Advances in Building Energy Research, 5(1), 109-127. https://doi.org/10.1080/17512549.2011.582350

Linden, P. F. (1999). The fluid mechanics of natural ventilation. Annual Review of Fluid Mechanics, 31(1), 201-238. https://doi.org/10.1146/annurev.fluid.31.1.201

Mediastika, C. E. (2005). Akustika bangunan: Prinsip-prinsip dan penerapannya di Indonesia (H. W. Hardani (ed.)). Erlangga.

Panero, J., & Zelnik, M. (2003). Dimensi manusia & ruang interior (D. Kurniawan (trans.)). Erlangga.

Poerbo, H. (1992). Utilitas bangunan buku pintar untuk mahasiswa arsitektur-sipil. Djambatan.

Prawitasari, F. (2019). Evaluasi pasca huni huntap pagerjurang ditinjau dari aspek fungsional. Jurnal SPACE, 1(2), 6-14. https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKEwis8M7Z2J70AhWN4XMBHe4UA7sQFnoECBMQAQ&url=https%3A%2F%2Fejournal.unhi.ac.id%2Findex.php%2Fspace%2Farticle%2Fdownload%2F583%2F447&usg=AOvVaw2vjkLQAYCVKJHQ3KHdC1RR

Preiser, W. F. E., Rabinowitz, H. Z., & White, E. T. (2015). Post-occupancu evaluation. Routledge Revivals.

Presiden Republik Indonesia. (2003). Undang-Undang Republik Indonesia Nomor 20 Tahun 2003 tentang Sistem Pendidikan Nasional. http://simkeu.kemdikbud.go.id/index.php/peraturan1/8-uu-undang-undang/12-uu-no-20-tahun-2003-tentang-sistem-pendidikan-nasional

Raihan, M. H. (2018). Evaluasi pasca huni terhadap aspek fungsional kawasan lembaga Perguruan Mujahidin Pontianak. JMARS: Jurnal Mosaik Arsitektur, 6(2), 180-188. https://doi.org/10.26418/jmars.v6i2.28926

Sari, L. H., Zahriah, Z., & Hefanirada, P. (2021). A Preliminary-study of environment evaluation (Case study: Houses in Aceh Province, Indonesia). IOP Conference Series: Earth and Environmental Science, 881(1), 12027. https://doi.org/10.1088/1755-1315/881/1/012027

Satwiko, P. (2008). Fisika bangunan. Andi.

Septiani, E. M. (2015). Persepsi pemustaka pada desain interior ruang baca di Kantor Perpustakaan dan Arsip Kota Kediri. Jurnal Ilmu Perpustakaan, 4(3), 71-80. https://ejournal3.undip.ac.id/index.php/jip/article/view/9727

Watson, C. (2003). Review of building quality using post occupancy evaluation. OECD Publishing. https://doi.org/10.1787/715204518780

Zhang, Y., Kacira, M., & An, L. (2016). A CFD study on improving air flow uniformity in indoor plant factory system. Biosystems Engineering, 147, 193-205. https://doi.org/10.1016/j.biosystemseng.2016.04.012

Share

COinS